Please refer to the main Schedule of Products page for more information.
Fittings – Plastic
Product type | Product scope/application | Specification | Year | Lead Free Applies |
---|---|---|---|---|
Acrylonitrile butadiene styrene (ABS) fittings
| Solid-wall acrylonitrile-butadiene-styrene (ABS) fittings for soil and waste discharge (low and high temperature) inside buildings, designed for jointing by means of elastomeric sealing rings, solvent cementing or integral dual-purpose sockets. | ISO 7682 Plastics piping systems for soil and waste discharge | 2003 | No |
Cross-linked polyethylene (PE-X) fittings | Fittings for use with crosslinked polyethylene (PE-X) for pressure heated and cold water applications. | AS/NZS 2537.2 Mechanical jointing fittings for use with crosslinked polyethylene (PE-X), Part 2: Plastics piping systems for hot and cold water installations – Crosslinked polyethylene(PE-X) – Fittings Note: See NoD 2017/4.4 | 2011 | Yes |
Macro composite fittings | Multilayer piping systems for heated and cold water installations inside buildings. | AS 4176.3 Multilayer piping systems for hot and cold water plumbing applications – Fittings Note: See NoD 2017/4.4 | 2010 | Yes |
Polybutylene (PB) fittings | Mechanical jointing fittings suitable for use as fixed joints with polybutylene plumbing pipes. | AS/NZS 2642.3 Polybutylene (PB) plumbing pipe systems Mechanical jointing fittings for use with polybutylene (PB) pipes for hot and cold water applications. Note: See NoD 2017/4.4 | 2008 | Yes |
Polyethylene (PE) fittings
| Fittings to be used with polyethylene pipe for the conveyance of water and other fluids. | AS/NZS 4129 Fittings for polyethylene (PE) pipes for pressure applications | 2020 | Yes |
Solid-wall polyethylene (PE) fittings for soil and waste discharge (low and high temperature) of DN 32 to 100. | AS/NZS 4401 Plastics piping systems for soil and waste discharge (low and high temperature) inside buildings - Polyethylene (PE) Note: See NoD 2017/4.4 | 2006 | No | |
Polyethylene (PE) fittings greater than DN 100 for sewerage and drainage applications, intended to be used where the pipeline is operating under gravity flow and the operating pressure is low. Including both plain and structured wall fittings. | AS/NZS 5065 Polyethylene and polypropylene pipes and fittings for drainage and sewerage applications Note: See NoD 2017/4.4 | 2005 | No | |
Polypropylene (PP) fittings
| Polypropylene (PP) fittings greater than DN 100 for sewerage and drainage applications, intended to be used where the pipeline is operating under gravity flow and the operating pressure is low. Including both plain and structured wall pipes and fittings. | AS/NZS 5065 Polyethylene and polypropylene pipes and fittings for drainage and sewerage applications Note: See NoD 2017/4.4 | 2005 | No |
Polypropylene (PP) fittings for soil and waste discharge (low and high temperature). This is applicable to PP fittings, and assemblies fittings, intended to be used for soil and waste discharge pipework for the conveyance of domestic waste waters (low and high temperature) and associated ventilation pipework. Fittings for jointing by means of elastomeric sealing rings or by butt fusion. | AS/NZS 7671 Plastics piping systems for soil and waste discharge (low and high temperature) inside buildings | 2010 | No | |
Polypropylene (PP) piping systems intended to be used for heated and cold water installations within buildings. | ISO 15874-3 Plastic piping systems for hot and cold water installations – Polypropylene (PP) – Fittings Note: See NoD 2017/4.4 | 2013 | Yes | |
Polypropylene (PP) piping systems intended to be used for heated and cold water installations within buildings. | ISO 15874-1 Plastic piping systems for hot and cold water installations – Polypropylene (PP) – General | 2013 | Yes | |
Polyvinyl chloride (PVC) fittings | PVC-U fittings (including gullies and expansion joints) for sewer, drain, waste and vent applications, intended to be used where the pipeline is operating under gravity flow and the operating pressure is low. Including plain and structured wall fittings. | AS/NZS 1260 PVC-U pipes and fittings for drain, waste and vent applications | 2017 | No |
PVC fittings for pressure applications where not exposed to direct sunlight. | AS/NZS 1477 PVC pipes and fittings for pressure applications | 2017 | No | |
Metric polybutylene (PB) fittings | Mechanical and fusion jointing fittings suitable for use as fixed joints with polybutylene pipes of the following types:
| AS 5082.2 Polybutylene (PB) plumbing pipe systems - Metric series - Mechanical and fusion jointing systems | 2007 | Yes |
Glass-filament-reinforced thermosetting plastic (GRP) fittings | Glass-reinforced thermoplastics (GRP) systems based on unsaturated polyester (UP) resin. Used for pressure and non-pressure drainage and sewerage applications. | AS 3571.1 Plastics piping systems - Glass-reinforced thermoplastics (GRP) systems based on unsaturated polyester (UP) resin - Pressure and non-pressure drainage and sewerage | 2009 | No |
Glass-reinforced thermoplastics (GRP) systems based on unsaturated polyester (UP) resin. For use in pressure and non-pressure water supply applications. | AS 3571.2 Plastics piping systems - Glass-reinforced thermoplastics (GRP) systems based on unsaturated polyester (UP) resin - Pressure and non-pressure water supply | 2009 | No | |
Plastic fittings with noise reduction | Noise reduction fittings made of a compound of polypropylene and inert mineral additives for use at intermittent operating temperatures up to 95°C. | WMTS-508 Plastics piping systems for soil and waste discharge – with noise reduction characteristics | 2013 | No |
Plastic waste outlets | A plastic waste outlet which may incorporate components made from either plastic or other materials. | AS 2887 Plastic waste fittings | 1993 | No |
Plastic fixture traps | Moulded or fabricated plastic waste fittings suitable for receiving intermittent liquid discharges at temperatures not exceeding 95°C. | AS 2887 Plastic waste fittings | 1993 | No |
Soil waste dump fittings | DN 80 or DN 100 plastics-bodied fitting that is utilised as soil waste dump point for mobile toilet waste disposal. | WMTS-482 Soil waste dump fitting | 2016 | No |
Plastic bodied flexible couplings | Plastic bodied couplings up to DN 300 with included elastomeric element that provides limited flexibility and are utilised in non-pressure rigid pipeline systems. | WMTS-519 Plastic Bodied Flexible Coupling | 2024 | No |
Plastic bodied fitting with intermediate flexible joints | Plastics bodied fittings of nominal sizes up to DN 300 with intermediate flexible joints for sewer or drain applications intended to be used where the pipeline is operating under gravity flow and the operating pressure is low. | WMTS-055 Plastic fittings – Connectors with flexible intermediate joints for drainage and sewerage applications | 2024 | No |
Offset pan connectors
| Injected moulded offset pan connectors. | WMTS-517 Offset pan connectors | 2016 | No |
Moulded or fabricated plastic waste fittings used to convey liquids not exceeding 95°C from a fixture to discharge pipework. | AS 2887 Plastic waste fittings | 1993 | No | |
PVC-U fittings for sewer drain, waste and vent application intended to be used where the pipeline is operating under gravity flow and the operating pressure is low. | AS/NZS 1260 PVC-U pipes and fittings for drain, waste and vent applications. | 2017 | No | |
Plastic waste fitting | Moulded or fabricated plastic waste fittings used to convey liquids not exceeding 95°C from a fixture to discharge pipework. | AS 2887 Plastic waste fittings | 1993 | No |
Fixture connector adaptor | Smooth bore plastic-bodied fixture connector adaptors with an adjustable offset used to provide flexibility at the point of installing fixtures to the sanitary plumbing system. | WMTS-536 Fixture connector adaptor | 2022 | No |