NCC 2022 Volume One - Building Code of Australia Class 2 to 9 buildings
Search the National Construction Code editions
Part B1 Structural provisions
The structural resistance of materials and forms of construction must be determined in accordance with the following, as appropriate:
| Application | Lift shaft vision panels more than 65,000 mm2, door panels, and lift shafts | Lift shaft vision panels less than or equal to 65,000 mm2 |
|---|---|---|
| Laminated glass | 10 mm (0.76 mm interlayer) | 6 mm (0.76 mm interlayer) |
| Toughened/laminated glass | 10 mm (0.76 mm interlayer) | 6 mm (0.76 mm interlayer) |
| Annealed glass with security polyester film coating | 10 mm | 6 mm |
| Safety wire glass | Not applicable | Subject to fire test |
| Polycarbonate sheet | 13 mm | 6 mm |
| Application | Lift shaft vision panels more than 65,000 mm2, door panels, and lift shafts | Lift shaft vision panels less than or equal to 65,000 mm2 |
|---|---|---|
| Laminated glass | 10 mm (0.76 mm interlayer) | 6 mm (0.76 mm interlayer) |
| Toughened/laminated glass | 10 mm (0.76 mm interlayer) | 6 mm (0.76 mm interlayer) |
| Annealed glass with security polyester film coating | 10 mm | 6 mm |
| Safety wire glass | Not applicable | Subject to fire test |
| Polycarbonate sheet | 13 mm | 6 mm |